Power Supply
This series includes the AD1020-05F, AD1024-12F, and AD1024-24F models, featuring a rugged and high-power-density design, specifically developed to meet space-saving requirements and industrial applications. All models come with built-in dry contact alarm signals and O-ring diodes, supporting redundant system configurations, and are equipped with overvoltage protection, overload protection, and short-circuit protection to ensure reliable operation. The design is flexible, allowing installation on T.35 rails or easily mounted on walls using the included mounting brackets. All models comply with RoHS standards, carry the CE mark, and are UL508 certified.
Product Features
1. Innovative design of industrial-grade rail-mounted power supply
2. Natural convection air cooling
3. Overvoltage protection
4. Overload protection
5. Short-circuit protection
6. Rail-mounted/clip-lock mounting for secure installation
7. Optional dry contact alarm signals/backup functionality
8. High power density
9. High reliability
10. Compact size, high efficiency, cost-effective
11. Complies with RoHS/UL/CE standards
12. 3-year warranty
13. Operating Environment
14. Operating temperature: -40°C to 50°C
15. Operating humidity: 5%-95% relative humidity, non-condensing
Downloads
Specifications
General specifications | |
project | specification |
Switching frequency | 66kHz |
Isolation Voltage | Input-Output:3000VAC / 4242VDCInput-FG:1500VAC / 2121VDCOutput-FG:500VAC / 710VDC |
Insulation resistance | 100MΩ(Input-Output @500VDC) |
as temperature | -40°C ~ +50°C (ambient temperature) |
Derating | From 50°C, the load is reduced by 2.5% per degree |
Storage temperature | -40°C ~ +85°C |
relative humidity | 5% ~ 95% RH (non-condensing) |
Temperature coefficient | ±0.04% change in output voltage per °C |
Mean time between failures (MTBF). | 100,000 hours minimum per MIL-HDBK-217F, 25°C GB |
Operational height | It can be used up to 2000 meters |
Mounting direction | Vertical |
Vibration resistance | Random vibration, frequency 10~500Hz, three-axis direction |
Enter the specifications | |
project | specification |
Input voltage | 100240VAC / 120370VDC |
Enter the frequency | 47~63Hz |
Inrush current (cold start) | 11A / 115VAC; 22A / 230VAC |
Rated input current | Max. 1A (Vi=100~240VAC) |
Leakage current | Input-output:0.25mAInput-FG:3.5mA(Vi=250VAC) |
Output specifications | |
project | specification |
Output voltage accuracy | ±1% |
Minimum load | 0% |
Line Regulation | ±1% (from lowest voltage to highest voltage load measurement) |
Load Regulation | ±1% from 20% to 100% rated load, 230VAC input |
Voltage trimming range | Min. ±10% |
Rated continuous load | 4A @5VDC、2A @12VDC、1A @24VDC |
Hold-up Time | Minimum 30ms (full load, 230VAC) |
Turn On Time | 300ms |
Rise Time | 10ms |
Fall Time | 35ms |
-
Model:AD1024F series