Power Supply

Power Supply

This series includes the AD1020-05F, AD1024-12F, and AD1024-24F models, featuring a rugged and high-power-density design, specifically developed to meet space-saving requirements and industrial applications. All models come with built-in dry contact alarm signals and O-ring diodes, supporting redundant system configurations, and are equipped with overvoltage protection, overload protection, and short-circuit protection to ensure reliable operation. The design is flexible, allowing installation on T.35 rails or easily mounted on walls using the included mounting brackets. All models comply with RoHS standards, carry the CE mark, and are UL508 certified.

Product Features

1. Innovative design of industrial-grade rail-mounted power supply
2. Natural convection air cooling
3. Overvoltage protection
4. Overload protection
5. Short-circuit protection
6. Rail-mounted/clip-lock mounting for secure installation
7. Optional dry contact alarm signals/backup functionality
8. High power density
9. High reliability
10. Compact size, high efficiency, cost-effective
11. Complies with RoHS/UL/CE standards
12. 3-year warranty
13. Operating Environment
14. Operating temperature: -40°C to 50°C
15. Operating humidity: 5%-95% relative humidity, non-condensing

Downloads

Specifications

General specifications

project

specification

Switching frequency

66kHz

Isolation Voltage

Input-Output3000VAC / 4242VDCInput-FG1500VAC / 2121VDCOutput-FG500VAC / 710VDC

Insulation resistance

100MΩ(Input-Output @500VDC

as temperature

-40°C ~ +50°C (ambient temperature)

Derating

From 50°C, the load is reduced by 2.5% per degree

Storage temperature

-40°C ~ +85°C

relative humidity

5% ~ 95% RH (non-condensing)

Temperature coefficient

±0.04% change in output voltage per °C

Mean time between failures (MTBF).

100,000 hours minimum per MIL-HDBK-217F, 25°C GB

Operational height

It can be used up to 2000 meters

Mounting direction

Vertical

Vibration resistance

Random vibration, frequency 10~500Hz, three-axis direction

Enter the specifications

project

specification

Input voltage

100240VAC / 120370VDC

Enter the frequency

47~63Hz

Inrush current (cold start)

11A / 115VAC 22A / 230VAC

Rated input current

Max. 1A (Vi=100~240VAC)

Leakage current

Input-output0.25mAInput-FG3.5mAVi=250VAC

Output specifications

project

specification

Output voltage accuracy

±1%

Minimum load

0%

Line Regulation

±1% (from lowest voltage to highest voltage load measurement)

Load Regulation

±1% from 20% to 100% rated load, 230VAC input

Voltage trimming range

Min. ±10%

Rated continuous load

4A @5VDC2A @12VDC1A @24VDC

Hold-up Time

Minimum 30ms (full load, 230VAC)

Turn On Time

300ms

Rise Time

10ms

Fall Time

35ms

  • Model:AD1024F series