Power Supply
This series includes the AD1240-12S, AD1240-24S, and AD1240-48S models, featuring a rugged and high-power-density design, specifically developed to meet space-saving requirements and industrial applications. All models come with built-in dry contact alarm signals and O-ring diodes, supporting redundant system configurations, and are equipped with overvoltage protection, overload protection, and short-circuit protection to ensure reliable operation. The design is flexible, allowing installation on T.35 rails or easily mounted on walls using the included mounting brackets. All models comply with RoHS standards, carry the CE mark, and are UL508 certified.
Product Features
1. Innovative design of industrial-grade rail-mounted power supply
2. Natural convection air cooling
3. Overvoltage protection
4. Overload protection
5. Short-circuit protection
6. Rail-mounted/clip-lock mounting for secure installation
7. Optional dry contact alarm signals/backup functionality
8. High power density
9. High reliability
10. Compact size, high efficiency, cost-effective
11. Complies with RoHS/UL/CE standards
12. 3-year warranty
13. Operating Environment
14. Operating temperature: -40°C to 50°C
15. Operating humidity: 5%-95% relative humidity, non-condensing
Downloads
Specifications
project | specification |
Switching frequency | 85kHz |
Isolation Voltage | Input-Output:3000VAC / 4242VDC |
Insulation resistance | 100MΩ (when Input-Output @500VDC). |
as temperature | -40°C ~ +50°C (ambient) |
Derating | The output power decreases by 2.5% per °C for every 50°C exceeded, up to a maximum of 70°C |
Storage temperature | -40°C ~ +85°C |
relative humidity | 5% ~ 95% RH (non-condensing). |
Temperature coefficient | ±0.04% output voltage deviation per °C |
Mean time between failures (MTBF). | ≥ 60,000 hours per MIL-HDBK-217F, 25°C GB |
Maximum work height | 2000 meters |
Mounting direction | vertical |
Vibration resistance | Random vibration 10~500Hz (three axes). |
Enter the specifications | |
project | specification |
Input voltage | 115/230VAC (±15% selective switching). |
Enter the frequency | 47~63Hz |
Inrush current (cold start) | 22A @ 115VAC; 44A @ 230VAC |
Rated input current | Maximum 5A @Vi=100~240VAC, 3A Max.@Vi=200~240VAC |
Leakage current | Input-Output:0.25mA; Input-FG:3.5mA(Vi = 250VAC) |
Output specifications | |
project | specification |
Output voltage accuracy | ±1% |
Minimum load | 0% |
Line Regulation | ±1% (low input to high input measurement). |
Load Regulation | ±1% (from 20% to 100% load rating @ 230VAC). |
Voltage trimming range | ± 10% (minimum). |
Rated continuous output current | 20A @ 12VDC、10A @ 24VDC、5A @ 48VDC |
Hold-up Time | ≥ 30ms (full load, 230VAC). |
Turn On Time | 1300ms |
Rise Time | 15ms |
Fall Time | 30ms |
-
Model:AD1240S Series