Power Supply

Power Supply

This series includes the AD1100-12F, AD1100-24F, and AD1100-48F models, featuring a rugged and high-power-density design, specifically developed to meet space-saving requirements and industrial applications. All models come with built-in dry contact alarm signals and O-ring diodes, supporting redundant system configurations, and are equipped with overvoltage protection, overload protection, and short-circuit protection to ensure reliable operation. The design is flexible, allowing installation on T.35 rails or easily mounted on walls using the included mounting brackets. All models comply with RoHS standards, carry the CE mark, and are UL508 certified.

Product Features

1. Innovative design of industrial-grade rail-mounted power supply
2. Natural convection air cooling
3. Overvoltage protection
4. Overload protection
5. Short-circuit protection
6. Rail-mounted/clip-lock mounting for secure installation
7. Optional dry contact alarm signals/backup functionality
8. High power density
9. High reliability
10. Compact size, high efficiency, cost-effective
11. Complies with RoHS/UL/CE standards

Downloads

Specifications

General specifications

project

specification

Switching frequency

85kHz

Isolation Voltage

Input-Output3000VAC / 4242VDC
Input-FG1500VAC / 2121VDC
Output-FG500VAC / 710VDC

Insulation resistance

100MΩ (when Input-Output @ 500VDC)

as temperature

-40°C ~ +50°C (Ambient)

Derating

2.5% reduction in output capacity per 50°C exceeded

Storage temperature

-40°C ~ +85°C

relative humidity

5% ~ 95% RH (non-condensing)

Temperature coefficient

±0.04% output voltage deviation per °C

Mean time between failures (MTBF).

60,000 hours (MIL-HDBK-217F, 25°C GB).

Height

2000 meters

Installation:

vertical

Vibration resistance

Random vibration 10~500Hz (3 axes)

Enter the specifications

project

specification

Input voltage

100240VAC / 120370VDC

Enter the frequency

47~63Hz

Inrush current (cold start)

22A @ 115VAC44A @ 230VAC

Rated input current

2.5A max (Vi = 100~240VAC)

Leakage current

Input-Output0.25mAInput-FG3.5mAVi = 250VAC

Output specifications

project

specification

Output voltage accuracy

±1%

Minimum load

0%

Line Regulation

±1% (from low voltage to high voltage measurement)

Load Regulation

±1% (from 20% to 100% load rating @230VAC)

Voltage trimming range

±10% (minimum)

Rated continuous output current

8A @ 12VDC4A @ 24VDC2A @ 48VDC

Hold-up Time

20ms (@230VAC full load).

Turn On Time

1300ms

Rise Time

13ms

Fall Time

25ms

  • Model:AD1100F Series